11 The Delay field is only active if one of the
Timed options is selected as the Processing
Mode. The default for Reader, Card, or Panel
Based Timed APB is zero seconds. This time can
be set from zero to 32,767 seconds.
12 The Card Formats available are dependent upon
which cards were configured for the Intelligent
Controller [on the Card Format tabs]. Up to eight
card formats can be selected for each reader.
13 Control Flags are special options that can be set
for the reader, and include:
Control Flags and Results
Set to deny a duress request
Works in a card and PIN mode only. Unless this option is
selected, duress is always enabled. Notify the monitoring
station you are under duress. Always one number higher
than the PIN code.
Log all access requests as used
If selected, logs all card reads as "door used," without
actually determining if the door is used. If unchecked,
logs all card reads, but waits until the door times out, or
the door is opened, to report. Deselect this option when
using anti-passback.
Do not pulse the door strike on rex
Door strike does not pulse upon free egress, however door
contact still gets shunted.
Filter CosDoor transaction
Throughout the door cycle the IC generates about 4 to 5
messages (door strike relay on, door strike relay off, door
opening, etc.). If more message are needed, this feature
can be disabled.
Require two-card control at this reader
Needs 2 valid cards within a 20 second window to grant
access. Used in vaults, high security areas.