379
2 The Port field is used to indicate the port on the
Intelligent Controller where this reader board is
located. The default Port is 6, but it can be set to
3, 4, or 5 as well.
3 Use the Number of Errors before Going Off-
Line field to indicate the number of tries the
panel should make to "talk" to the communica-
tion server [without receiving an understandable
answer] before tripping the offline trigger. This
field defaults to 3.
4 Select the Enable Communication with SIO
check box only when the board is installed (not
before). The default for this box is selected.
Create an ADV for the Reader Module
5 Click the Add ADV button to call the Abstract
Device Record – SIO Board window.
6 The designation "SIO Board #" is appended to
the Intelligent Controller Name. If more than
one SIO Board is configured for the Intelligent
Controller, the board numbers increment auto-
matically, to make each name unique. This name
can be changed.
7 Select each Action for the Reader Module, set its
Priority, and make any other changes necessary
on the ADV window.
NOTE: Refer to the "Abstract Devices" section of this
chapter for details on setting up ADVs.
8 Click the OK button to save the ADV and return
to the Basic tab.
Programming