U option: Available with all PW-2000 series panels.
Allows the user to change the number of cards the
panel supports. Selecting more cards reduces the
number of buffers available to store events when the
panel is not online with the computer [or heavy
traffic prevents immediate transmission of all
events].
OH (25 bit card number plus site code):
Available for use with firmware later than 8.03.
Allows special card format applications.
Initialization Command
The Initialization Command field displays the
command string sent to the panel at initialization,
based on the Advanced Options selected. Note that
as an option is selected or deselected, a
corresponding string in the Initialization Command
field is added or removed.
Number of Cards (U Option)
The Number of Cards option allows you to enter the
number of cards for the panel, if the U advanced
option is selected.
Outputs for Duress
The Outputs for Duress (Duress Option) is only
available with the PW-2000 with 8.03 firmware.
When configured for PIN operation, if a PIN is used
with a value that is one number different from the
valid PIN, then the output defined in Outputs for
Duress will pulse. When configured with firmware
later than 8.03, then 2 outputs can be selected.