62
8. Troubleshooting
Refer to Table 8-1 for resolution of common problems. For additional technical support, please contact Impinj. For units not
purchased directly from Impinj, please contact your VAR directly.
Table 8-1 Troubleshooting
Problem Solution
The reader’s default page does not load.
Most likely the reader operating system is still booting or
TCP/IP connectivity has been lost. Retry or “ping” the
reader to verify connectivity. If more than 50 seconds
have elapsed since power was applied, disconnect and
reconnect power, then re-attempt to ping the unit after 50
seconds.
Java applet does not load after selecting “RFID” from
default page.
Verify that the PC’s web browser has Java Runtime
Environment (JRE) of version 1.4.2 or later. The latest
version of JRE may be installed from:
http://java.com/en/download/manual.jsp
“Initializing” or “Calibrating” dialog boxes do not
disappear.
The reader has likely locked up. Power cycle the reader.
Tags/sec rate varies when configuration settings are
changed.
This is normal. Currently, the Maximum Throughput
mode should have >200 tags/sec, while Dense-Reader
or Initialization modes are ~100 tags/sec. Some transmit
frequencies will be better than others (no interference or
less noise). Best rates will be achieved with 10 to 30 tags
within range.
None of the recommend actions fixes the problem. Power-cycle the reader