Speedway Reader IPJ-R1000 for Gen 2 UHF RFID
49
Parameter Name Format Description
Incompatible
Upgrade/Downgrade
Path |
Incompatible Upgrade/Downgrade Path: Upgrade
failed because upgrading/downgrading to the intended
SOP version or type is not allowed by current image.
Flash Programming
Failed |
Flash Programming Failed: Failed to write the flash
memory.
Flash Programming
Failed |
Flash Programming Failed: Failed to burn the flash.
Current Image
Invalidated |
Current Image Invalidated: The current image has
been invalidated by a previous “fallback” command.
No Fallback Image
Available |
This reason applies to the rejection of multiple
commands following a “fallback” commands.
Generic Error >
Generic Error: Download error other than those
specified above.
PrimaryImageType STRING
The type of image stored in the primary (currently
defaults to Linux)
PrimaryImageSystemVersion STRING
The version string of the primary image system
partition
PrimaryImageConfigVersion STRING
The version string of the primary image configuration
partition
SecondaryImageType STRING
The type of image stored in the secondary (currently
defaults to Linux)
secondaryImageSystemVersion STRING
The version string of the secondary iamge system
partition
secondaryImageConfigVersion STRING
The version string of the secondary image
configuration partition
Following an upgrade command, the UpgradeStatus can take the following values:
Idle: the reader is not performing any upgrade related activity.
Contacting Server: the reader is contacting the file server to download either the metafile or the upgrade image file.
Downloading: the reader is downloading either the metafile or the upgrade image file.
Download Failed: the download failed.
No upgrade: the reader does not need to perform an upgrade because one of the following scenarios: (detailed reasons
are given in the command response parameter as listed in Table 7-14)
o The upgrade-mode as specified by the metafile is auto and the image specified by the metafile is no newer
than the current one.
o The upgrade-mode as specified by the metafile is forced and the image specified by the metafile is the same
as the current one.
o The upgrade image file downloaded from the server carries image with the same version as the current one.
o The partition versions specified in the metafile or in the image downloaded are not allowed as a compatible
upgrade/downgrade path.
Bad Config: the metafile downloaded is invalid due to bad data entry syntax, missing data entries, or other
possibilities.
Bad Image: the upgrade image file is invalid due to:
o CRC failure in the upgrade image file
o Version numbers not matching those in the metafile that triggered the download of the image
o The image file is corrupted for other reasons
Erasing: the secondary image is being erased before the new upgrade image is programmed.
Programming: the new image is being programmed.
Done: the upgrade image has been successfully committed to flash and is ready to be activated. For each abnormal status, a
Reason parameter is given to indicate the reason for the status. The reason values are given in Table 7-14.