Sub-Mode 4 (Set Sleep Code)
EXPLANATION: The sleep code is used to disable all Relay A and function codes from the keypad. This feature is
most commonly used in applications where no entry is desired after hours. Relay B codes will still be valid from the
keypad. By connecting both relays in parallel, managers may be assigned RelayB codes and still gain access. While in
the SLEEP MODE, the yellow and red LED's will flash approximately once every 3 seconds. To initialize the system
back to normal, simply re-enter the sleep code. Should you lose or forget your sleep code and the unit is in the sleep
mode see the Unit Reset instructions on pages 6 & 7.
To program or change your sleep code enter the following;
(MASTER CODE) + 4 + (SLEEP CODE)
Should you make a code entry error, simply press the * key and enter the correct code. You may select any 4 digit sleep
code you wish. If you receive an ERROR, you must select another code as it is already in use. The unit will respond
with a GOOD BEEP with the acceptance of the new Sleep Code and you will be exited from the program mode.
♦
♦♦
♦
Sub-Mode 5 (Set Latch Code)
EXPLANATION: The Latch Code toggles the state of the main relay (A) of the circuit board. The red LED will light if
the relay is in the latched position. The latch code is useful in applications where the gate is desired to hold open. If the
operator's close circuit is controlled by loops, timers, etc., they will be overridden by the latched state of the relay and the
gate will hold open. An "OPEN-OVERRIDE" circuit must exist in the operator in order to utilize this function. If your
gate cycles when this code is entered, your operator is not set up to utilize this function. Your local dealer or distributor
should be able to assist you if you have any specific questions.
To program or change your latch code enter the following;
(MASTER CODE) + 5 + (LATCH CODE)
Should you make a code entry error, simply press the * key and enter the correct code. You may select any 4 digit latch
code you wish. If you receive an ERROR, you must select another code as it is already in use. The unit will respond
with a GOOD BEEP with the acceptance of the new Latch Code and you will be exited from the program mode. When
the latch code is entered the RED Led will light and the gate will hold open. When the latch code is entered again the
RED Led will go off and the gate will close. NOTE: On gates with a timer to close the “TIMED DURATION” starts
when the latch code is released.
♦
♦♦
♦
Sub-Mode 6 (Set Relay Output Times)
To set or change a relay output time enter the following;
(MASTER CODE) + 6 + (RELAY #) + (RELAY OUTPUT TIME) in seconds
The Relay # corresponds to which relay to set. 1 = Relay A, 2 = Relay B. Should you make a code entry error, simply
press the * key and enter the correct code. Your output time is set on both relays from the factory at approximately 1/2
seconds "00". If a longer output time is desired, enter a two digit number corresponding to the number of seconds
between "00" and "99". By entering "00" the output time is set to approximately 1/2 seconds which is ideal for most
operators.